
Scope 1, 2 and 3 emissions explained

If you’re responsible for your organisation’s carbon reporting, you already know the scopes exist. The harder questions are which of them you’re required to report, who in your business holds the data, and how to produce numbers an auditor will accept. This guide covers scope 1 and 2 emissions, the difference between them, and scope 3, with worked examples and the mistakes we see most often. It focuses on the UK and Australia, with pointers to other regimes.
Scope 1, 2 and 3 come from the GHG Protocol, the most widely used standard for measuring and reporting greenhouse gas emissions. They split a footprint by who controls the source. The definitions here follow the current GHG Protocol standards, which are being revised, with a consolidated standard targeted for Q4 2028.
| Scope | What it covers | Examples | Your control | Data usually held by |
|---|---|---|---|---|
| Scope 1 | Direct emissions from sources you own or control | Boilers, company vehicles, refrigerant leaks | Direct | Facilities, fleet |
| Scope 2 | Indirect emissions from the energy you buy | Purchased electricity, steam, heating and cooling | Through what you buy | Facilities, property |
| Scope 3 | All other indirect emissions in your value chain | Purchased goods, business travel, waste, use of sold products | Influence only | Procurement, finance |
Why the three scopes matter
The scopes decide what you report, who can act, and what buyers ask for.
- Regulation. The rules table later in this guide shows what each regime asks for, and the early periods often give scope 3 relief.
- Customers. Buyers increasingly ask suppliers for scope 1 and 2 emissions, because those become part of the buyer’s scope 3.
- Reduction. Each scope has different levers, so a split footprint shows you where to act first.
- Assurance. The data behind scope 1 and 2 needs a clear trail to source.
What are scope 1 and 2 emissions?
Scope 1 emissions are direct greenhouse gas emissions from sources your organisation owns or controls. The GHG Protocol groups them into four types:
- Stationary combustion: burning fuel in boilers, furnaces and generators on your sites
- Mobile combustion: fuel used in vehicles and equipment you own or control
- Fugitive emissions: leaks, such as refrigerant gases escaping from air conditioning and refrigeration
- Process emissions: emissions from industrial or chemical processes
Scope 2 emissions are indirect emissions from the generation of the electricity, steam, heating and cooling you buy and consume. The emissions don’t happen on your site. They happen at the power station or heat plant that supplies you, but they exist because of your demand.
Together, scope 1 and 2 emissions are usually the first thing organisations measure, because the data sits within your own operations. They’re also what most regimes require first. UK SECR requires quoted companies to report global scope 1 and 2, and large unquoted companies and LLPs to report their UK scope 1 and 2. The UK government notes that SECR primarily focuses on scope 1 and 2 (see its scope 3 call for evidence). AASB S2 in Australia requires scope 1 and 2 from the first reporting period.
Both are calculated the same way: activity data, such as litres of fuel or kilowatt hours of electricity, multiplied by an emission factor. In the UK, the government publishes annual conversion factors for company reporting. The factor you choose changes the answer, which is why we wrote about why the emission factor database matters more than the method.
The difference between scope 1 and 2 emissions
The difference between scope 1 and 2 emissions comes down to where the emissions physically occur, and who controls the source.
- Scope 1: emissions occur at a source you own or control. You decide what fuel it burns and how often it runs.
- Scope 2: emissions occur at someone else’s power station or heat plant. You influence them through how much energy you use and what you choose to buy.
A simple example shows the line. A gas boiler heating your office is scope 1, because the fuel burns on your premises. An electric heat pump heating the same office is scope 2, because the emissions come from generating the electricity. Swapping one for the other moves emissions from scope 1 to scope 2. Whether your total falls depends on how clean your electricity is and how efficient the equipment is.
The two also differ in how you reduce them:
- Scope 1 falls through efficiency, fuel switching, electrifying equipment and fixing leaks.
- Scope 2 falls through using less electricity, generating your own, or buying electricity with lower emissions.
Scope 2 also has a quirk. Under the GHG Protocol’s Scope 2 Guidance, you can calculate it two ways:
- Location-based: uses the average emission factor of the grid where you use the electricity.
- Market-based: reflects your contractual choices, such as energy attribute certificates or power purchase agreements.
Companies with operations in markets that offer these instruments report both. Standards based on IFRS S2, including AASB S2 and UK SRS, require the location-based figure and information about any contractual instruments. The GHG Protocol is revising its Scope 2 rules, so check its latest guidance before you build your method.
Worked example: scope 2, both methods
Illustrative factors only. They are not published factors. Use your own published factors for the correct year and region.
An office uses 50,000 kWh of electricity in the year.
- Location-based: 50,000 kWh × 0.20 kgCO2e per kWh (grid average) = 10,000 kg, or 10.0 tCO2e.
- Market-based: 40,000 kWh is covered by renewable energy certificates (factor 0). The remaining 10,000 kWh uses the supplier’s residual factor of 0.40 kgCO2e per kWh = 4,000 kg, or 4.0 tCO2e.
Same electricity, two valid figures. Report both where the standard asks for it, and be clear which one you use for targets.
What are scope 3 emissions?
Scope 3 emissions are all other indirect emissions that occur in your value chain, both upstream and downstream. The Scope 3 Standard divides them into 15 categories.
Upstream categories
- Category 1: Purchased goods and services
- Category 2: Capital goods
- Category 3: Fuel- and energy-related activities not included in scope 1 or 2
- Category 4: Upstream transportation and distribution
- Category 5: Waste generated in operations
- Category 6: Business travel
- Category 7: Employee commuting
- Category 8: Upstream leased assets
Downstream categories
- Category 9: Downstream transportation and distribution
- Category 10: Processing of sold products
- Category 11: Use of sold products
- Category 12: End-of-life treatment of sold products
- Category 13: Downstream leased assets
- Category 14: Franchises
- Category 15: Investments
Scope 3 is usually the hardest to measure, because the data sits with other organisations. CDP’s analysis found that supply chain emissions are, on average, 11.4 times higher than a company’s own operational emissions. Most of your footprint can sit outside your walls, with suppliers who may never have measured their emissions.
You can estimate scope 3 in three main ways: spend-based (using what you spent), average-data (using quantities and average factors) and supplier-specific (using suppliers’ own figures). Our guide to spend-based versus supplier-specific data explains when each is enough. To understand why collecting supplier data is the real challenge, read why Scope 3 supplier data collection is so hard, and for the case for starting early, see the business case for Scope 3 carbon tracking.
Prioritising scope 3
You don’t need to measure all 15 categories on day one. The GHG Protocol sets out criteria for deciding which are relevant. In practice, screen each category against four questions:
- Size: is it likely to be a large share of your footprint?
- Influence: can you realistically change it?
- Risk: is a regulator, customer or investor likely to ask for it?
- Data: how good is the data you can get?
Start with a spend-based screen of everything, then replace estimates with supplier data for your largest categories first. Record why you excluded any category. An auditor will ask.
Scope 3 gets easier when suppliers calculate once and share with every customer who asks. See how supply chain engagement works.
Scope 1, 2 or 3? A decision guide
| Situation | Usually | Why |
|---|---|---|
| Gas boiler in a building you own or control | Scope 1 | Fuel burned under your control |
| Fuel in company-owned or controlled vehicles | Scope 1 | Fuel burned in vehicles under your control |
| Electricity for company-owned or controlled electric vehicles, charged at your sites or at public points | Scope 2 | Purchased electricity consumed by vehicles you control |
| Company-owned or controlled electric vehicles charged at employees' homes | Scope 2 in most guidance, but check | Treatment varies depending on whether the company pays for or reimburses the electricity, so agree an approach with your assurer and document it |
| Leased vehicles you operate | Scope 1 or 2, or scope 3 (category 8) | Depends on your consolidation approach and the lease type |
| Employee using a personal car for business | Scope 3 (category 6) | Vehicle not under your control. Under SECR, large unquoted companies and LLPs must also report it as grey fleet |
| Employees commuting in their own cars, including electric ones | Scope 3 (category 7) | Outside your boundary |
| Leased office where you buy the energy | Scope 2 under operational control, or scope 3 (category 8) | Depends on your approach and the lease type |
| Heat network or district cooling | Scope 2 | Purchased heat or cooling |
| Remote working | Scope 3 (commuting or optional reporting) | Outside your boundary |
| Franchises | Scope 3 (category 14) for the franchisor | Franchisees report their own scope 1 and 2 |
Whichever approach you choose (operational control, financial control or equity share), apply it consistently and document it.
Which rules apply to you?
Correct as of 24 November 2026. These regimes change often, so check the current position before you rely on this table.
| Regime | Applies to | Scopes required | Timing |
|---|---|---|---|
| UK SECR | Quoted companies, and large unquoted companies and LLPs (check the Companies Act size tests) | Scope 1 and 2 for all companies in scope. Grey fleet (business travel in employee-owned or hire vehicles where the company buys the fuel, a scope 3 item) applies only to large unquoted companies and LLPs | In force |
| UK SRS | UK-listed companies | Scope 1, 2 and 3 | Comply or explain, for periods beginning on or after 1 January 2027, with one year of relief for scope 3 |
| AASB S2 (Australia) | Entities in three phased groups under the Corporations Act | Scope 1 and 2 from the first reporting period, scope 3 from the second | Group 1 from 1 January 2025, Group 2 from 1 July 2026, Group 3 from 1 July 2027 |
| EU CSRD and ESRS | In-scope EU entities, narrowed under the Omnibus changes | Scope 1, 2 and 3 where material | Revised ESRS apply to financial years starting on or after 1 January 2027 |
| California SB 253 | Large US entities doing business in California | Scope 1 and 2 first, then scope 3 | First scope 1 and 2 reports were due on 10 November 2026. On 9 November the Ninth Circuit found the scope 3 requirement and SB 261 likely unconstitutional and sent the scope 3 question back to the district court, so the case is continuing |
| Customer and supplier programmes, such as NHS England | Suppliers on in-scope contracts | Varies, often all relevant scope 3 | Contract dependent |
If you only supply to a regulated customer, you may never be directly in scope and still be asked for data. Check your contracts as well as your own obligations. See our guide to the NHS 2027 carbon reduction plan for an example.
Base year and recalculation
Your base year is the reference point for targets and trends. Pick a year with reliable data and set a policy for recalculating it when something structural changes, such as an acquisition, a divestment, a change in methodology, or a discovered error above your threshold. Without a stated policy, year-on-year comparisons become hard to defend.
Common mistakes
- Changing boundaries between years without recalculating the base year
- Missing refrigerant top ups, a frequent scope 1 gap
- Mismatched emission factors: the wrong year, the wrong region, or a mix of sources
- Double counting across scopes, for example with leased assets
- Netting off offsets against reported scope figures
- No scope 3 screening record, so exclusions can’t be justified
- No audit trail from the reported number back to invoices and meter reads
Who holds the data?
| Data | Typically owned by |
|---|---|
| Electricity, gas, heating | Facilities or property |
| Fuel and fleet | Fleet or operations |
| Refrigerants | Facilities or maintenance contractors |
| Purchased goods and services | Finance or procurement |
| Supplier-specific data | Procurement |
| Travel and commuting | HR or finance |
Agree owners and deadlines early. Most reporting delays come from data requests that lack a named owner.
Getting assurance-ready
Auditors test scope 1 and 2 first, and the checklist below is what they tend to ask for:
- A documented boundary and consolidation approach
- A documented base year and recalculation policy
- Source evidence for every activity data point, such as invoices, meter reads and fuel cards
- Emission factor sources and versions recorded
- Calculation logs showing inputs, factors and outputs
- Scope 3 screening results and the rationale for exclusions
- A review and sign-off trail
A 90-day starter plan
| Weeks | Focus |
|---|---|
| 1 to 2 | Set the boundary, name data owners and choose a base year |
| 3 to 6 | Collect scope 1 and 2 data, by site and by month |
| 7 to 10 | Calculate, quality-check, and document sources and factors. See how regional emission factors help multi-site organisations |
| 11 to 12 | Screen scope 3, shortlist your top suppliers and plan engagement |
Scope 1, 2 and 3 questions answered
Do I have to report all three scopes? It depends on the regime. SECR focuses on scope 1 and 2, plus grey fleet for large unquoted companies and LLPs. UK SRS and AASB S2 include scope 3, with relief in the early period. Voluntary frameworks and customers often ask for all three.
Which scope is the biggest? For many organisations, scope 3. It depends on your sector, so measure rather than assume.
Where do business travel and commuting fall? In scope 3, unless the vehicle is owned or controlled by your organisation, in which case it’s scope 1 or 2.
Is electricity for electric vehicles scope 1 or 2? Scope 2, when the vehicle is owned or controlled by your organisation, including when you charge it at public points. Home charging can be treated differently depending on whether the company pays or reimburses the electricity, so document your approach. Fuel burned in vehicles you own is scope 1.
Do offsets reduce my reported scope figures? No. Report gross emissions, and disclose offsets or removals separately.
What’s the difference between location-based and market-based? Location-based uses the average grid factor, and market-based reflects your contracts. See the section above on the difference between scope 1 and 2 emissions, which includes a worked example.
If you’d like help building your scope 1, 2 and 3 inventory, book a call with our team.

Be a net-zero hero
At eco-shaper, we drive action on climate change and streamline carbon footprinting. For example, we can help calculate emissions across the entire ecosystem that companies work across and produce automated reporting based on outcomes. Contact us to be part of our research group on
